Taolo e hole ea waelese ea indasteri DH01R-4W-26K

Lehae|industrial remote control|Taolo e hole ea waelese ea indasteri DH01R-4W-26K

Taolo e hole ea waelese ea indasteri DH01R-4W-26K

Kopo:e sebelisetsoang lisebelisoa tse fapaneng tsa indasteri

1.Boholo 26 Welding machine automation welding and welding operator.Turn Rolls 1.Using frequency hopping transmission technology.

2.Sebaka sa phetisetso e se nang lithibelo ke 200 limithara.

3. Boholo 4 liteishene tsa tlhahiso ea analoge 0-10V (sebaka sa ponts'o se ka etsoa ka mokhoa o ikhethileng): tshehetso 2 liteishene tsa tlhahiso e atolositsoeng ea potentiometer ea dijithale;

4. 2 lisebelisoa tsa analoge; mme e hlahiswa ho remote control, sebaka sa pontšo se ka etsoa ka mokhoa o ikhethileng.

5. 1 tlhahiso ea ho emisa ho emisa ka tšohanyetso hangata ho koalehile lebitso.


  • Moralo oa tšebeliso e tlase ea matla
  • Ho bonolo ho e sebelisa

Tlhaloso

1.Product model

 

Mohlala: DH01R-4W-26K

Applicable equipment:various industrial equipment

2.Product accessories diagram

Hlokomela: You can choose one of the three antennas. The suction cup antenna is standard by default.

3.Product model description

Hlokomela:
① DH01R series, if the suffix contains T, it means with emergency stop output;without T, it means without emergency stop output.

②If there is no analog output, there is no need to remark 0W or 0R; the analogquantities W1, W2, W3, and W4 default to 0-10V analog voltage output; at the same time, W1 and W2 can be expanded to 2 isolated digital potentiometer outputs, with a range of 0 -5K ohms, ½ watt; resolution: 20 ohms. The two digital potentials can be used to control the welding current and welding voltage of the welding machine. If the digital potentiometer output is required, user notes are required.

④Analog input, ranging from 1 to 2, e bontšang hore li teng 1 to 2 lisebelisoa tsa analoge(boholo 2 dikanale); ha ho na le tlhahiso ea analoge, o hloka ho ela hloko mofuta oa motlakase oa phallo ea analog (moamoheli oa rona oa kamehla ho 0 -5V, mosebedisi ka boela hlokomela e le 4-20 mA kapa 0-10V, etc.) le lethathamo le tsamaellanang la pontšo ea bongata ba analoge (ka mohlala: pontsho 0-100 volts kapa 0-1000 li-amps)

Lipalo tsena tse peli tsa analoge li ka sebelisoa e le lipontšo bakeng sa motlakase oa welding oa hajoale le oa welding.

4.Likaroloana

1)Maximum 26 Welding machine automation welding and welding operator.Turn Rolls 1.Using frequency hopping transmission technology;
2)Maximum 4 liteishene tsa tlhahiso ea analoge 0-10V (sebaka sa ponts'o se ka etsoa ka mokhoa o ikhethileng): tshehetso 2 liteishene tsa tlhahiso e atolositsoeng ea potentiometer ea dijithale;
3)2 analog inputs; mme e hlahiswa ho remote control, sebaka sa pontšo se ka etsoa ka mokhoa o ikhethileng
4)1 channels of emergency stop relay output normally closed contacts;
5) Powered by 3 Libetri tsa AA, low power consumption design;
6) Wireless operation distance is 200 limithara;
7)Protection grade IP67;
8)With cross switch operation, supports two 4-direction cross switches;
9)Back strap design.

5.Remote control switch description

6.Display content introduction

W1 knob value: W1: 0-1000 (parameter adjustable 0-9999)
W2 knob value: W2: 0-5000 (parameter adjustable 0-9999)
W3 knob value: W3: 0-5000 (parameter adjustable 0-9999)
W4 knob value: W4: 0-5000 (parameter adjustable 0-9999)
ADC1 feedback display: 0-1000 (parameter adjustable 0-5000)
ADC2 feedback display: 0-1000 (parameter adjustable 0-5000)

Low voltage: The remote control battery is too low, please replace the battery.

Network dropped: The wireless signal is interrupted. Please check the power of the receiver, power it on again, and restart the remote control.

7.Remote control function operation instructions

1) Turn on the remote control
When the receiver is powered on, the receiver working indicator flashes; install two AA batteries in the remote control, turn on the power switch, and the display shows a value,indicating successful startup. The receiver working indicator light becomes solid.
2)Switch and button functions
Any operation of the twist switch and button on the remote control can control the corresponding switch signal output point on the receiver. All switch signal output points on the receiver are normally open signals by default;
3)W1-W4 speed adjustment
Fetola likonopo ho W1-W4 ka mokhoa o sa tsotelleng ho sebelisa lets'oao le ts'oanang la analog kapa lets'oao la potentiometer qetellong ea moamoheli.. Letšoao la tlhahiso ea analoge qetellong ea moamoheli le fetoha lets'oao la motlakase oa 0-10V, mme letshwao la potentiometer le fetohela ho 0-5K;
4) Mosebetsi oa tšohanyetso oa ho emisa
Ha konopo ea ho emisa ts'ohanyetso e tobetsoa, liphetho tsohle tsa lets'oao la switjha li khaotsoe 'me tlhahiso ea analoge e hangoa; ka mor'a hore setopo sa tšohanyetso se lokolloe, matšoao ohle a switjha a khutlisetsoa mme tlhahiso ea analoge e khutlisoa; 5 seconds after the remote control is turned off, all switch signal outputs are disconnected and the analog quantities remain unchanged. When the remote control is turned on, the switch signal outputs automatically recover;
5)Parameter menu (users are prohibited from modifying it privately)
Some functions of the remote control can be adjusted through parameters. When the display W1=0, press the K9-B button 3 times in a row, and then press the K9-A button 3 times in a row to enter the parameter menu; K9-A le K9-B linotlolo ho leqephe ka har'a menu ebe u khetha li-parameter; tšoara K1-A, ebe o tobetsa konopo ea K9-A/B ho fetola liparamente;
Tlosa ho menu ea parameter: khetha ho boloka kapa ho se boloke, ebe o tobetsa konopo ea K1-A ho netefatsa ho tsoa;
Sehlopha sa F1W1: Boleng ba mofuta oa ponts'o ea knob ea W1 skrineng sa ponts'o, fetohang ho tloha 0 to 9999;
Sehlopha sa F2W2: Boleng ba mofuta oa ponts'o ea knob ea W2 skrineng sa ponts'o, fetohang ho tloha 0 to 9999;
Sehlopha sa F3W3: Boleng ba mofuta oa ponts'o ea knob ea W3 skrineng sa ponts'o, fetohang ho tloha 0 to 9999;
Sehlopha sa F4W4: The display range value of the W4 knob on the display screen, fetohang ho tloha 0 to 9999
F5A1 range: Display ADC1 feedback display range value, 0-5000 adjustable;
F6A2 range: Display ADC2 feedback display range value, 0-5000 adjustable;
Alarm current: Set the alarm value for ADC1 and ADC2 feedback display. When ADC1 and ADC2 exceed this value, the remote control display will alarm; when this value is 0,the alarm function is invalid;

8.Remote control electrical characteristics

 

9.Remote control size

 

The final interpretation right of this product belongs only to our company.

Ga tlhaloso paramethara

Teknoloji ea Wixhc

Re baetapele indastering ea CNC, e sebetsanang le phetiso ea waelese le CNC Motion Control bakeng sa ho feta 20 lilemo. Re na le mahlale a mangata a patisaneng, mme lihlahisoa tsa rona li rekisa hantle ho feta 40 linaha ho potoloha le lefatše, bokella ts'ebeliso e tloaelehileng ea hoo e batlang e 10000 bareki.

Li-Tweets tsa haufinyane

Koranta

Ingolise ho fumana litaba tsa morao-rao le tlhaiso-leseling. Se ke oa tšoenyeha, re ke ke ra romella spam!