Descripción
1.Modelo producto

Modelo: DH01R-4W-26K
Equipamiento aplicable:various industrial equipment
2.Diagrama accesorios ar producto

Hñeti: Dar tsa̲ da 'ñets'i 'na hñu ya antenas. Antena ventosa ar estándar ya defecto.
3.Product model description

Hñeti:
① DH01R series, if the suffix contains T, it means with emergency stop output;without T, it means without emergency stop output.
②If there is no analog output, there is no need to remark 0W or 0R; the analogquantities W1, W2, W3, and W4 default to 0-10V analog voltage output; at the same time, W1 and W2 can be expanded to 2 isolated digital potentiometer outputs, with a range of 0 -5K ohms, ½ watt; resolution: 20 ohms. The two digital potentials can be used to control the welding current and welding voltage of the welding machine. If the digital potentiometer output is required, user notes are required.
④Analog input, ranging from 1 Pa 2, indicating that there are 1 Pa 2 Entradas analógicas(maximum 2 Canales); when there is an analog input, you need to note the voltage range of the analog input (our receiver defaults to 0 -5V, the user can also note as 4-20 mA or 0-10V, etc.) and the corresponding display range of the analog quantity (for example: display 0-100 volts or 0-1000 amps)
These two analog quantities can be used as displays for welding current and welding voltage.
4.Ya 'befi
1)Maximum 26 Salidas relé;
2)Maximum 4 canales salida analógica 0 — 10V (Rango visualización ar tsa̲ da personalizar): Soporta 2 Canales salida potenciómetro 'bede aislado extendido;
3)2 analog inputs; ne bí gi 'ñudi ja ar mando mbi, Rango visualización ar tsa̲ da personalizar
4)1 channels of emergency stop relay output normally closed contacts;
5) Powered by 3 Baterías AA, low power consumption design;
6) Wireless operation distance is 200 Metros;
7)Protection grade IP67;
8)With cross switch operation, supports two 4-direction cross switches;
9)Back strap design.
5.Descripción interruptor control remoto

6.Display content introduction

W1 knob value: W1: 0-1000 (parameter adjustable 0-9999)
W2 knob value: W2: 0-5000 (parameter adjustable 0-9999)
W3 knob value: W3: 0-5000 (parameter adjustable 0-9999)
W4 knob value: W4: 0-5000 (parameter adjustable 0-9999)
ADC1 feedback display: 0-1000 (parameter adjustable 0-5000)
ADC2 feedback display: 0-1000 (parameter adjustable 0-5000)

Xí hñets'i'i tensión: Ar bateriya ar mando mbi xi xki xí hñets'i'i, Reemplace ar bateriya.

Red caída: Ar señal inalámbrica da k'ats'i ma. Compruebe ár nts'edi ar receptor, Encender nä'ä ar nuevo, ne reinicie ar control remoto.
7.Instrucciones funcionamiento ar función control remoto
1) Turn on the remote control
When the receiver is powered on, the receiver working indicator flashes; install two AA batteries in the remote control, Encienda interruptor encendido, and the display shows a value,Nä'ä indica 'nar inicio exitoso. The receiver working indicator light becomes solid.
2)Switch and button functions
Any operation of the twist switch and button on the remote control can control the corresponding switch signal output point on the receiver. All switch signal output points on the receiver are normally open signals by default;
3)W1-W4 speed adjustment
Rotate the knobs in W1-W4 arbitrarily to operate the corresponding analog output signal or potentiometer signal at the receiver end. The analog output signal at the receiver end defaults to a 0-10V voltage signal, and the potentiometer signal defaults to 0-5K;
4) Emergency stop function
When the emergency stop button is pressed, all switch signal outputs are disconnected and the analog output is disconnected; after the emergency stop is released, all switch signals are restored and the analog output is restored; 5 seconds after the remote control is turned off, all switch signal outputs are disconnected and the analog quantities remain unchanged. When the remote control is turned on, the switch signal outputs automatically recover;
5)Parameter menu (users are prohibited from modifying it privately)
Ra 'befi ar mando mbi ar xi ajustar a través de parámetros. When the display W1=0, press the K9-B button 3 times in a row, and then press the K9-A button 3 times in a row to enter the parameter menu; K9-A and K9-B key to page through the menu and select parameters; hold down K1-A, and then press the K9-A/B button to modify parameters;
Po̲ni jar menú parámetros: Da 'ñets'i guardar wa hindi guardar, and then press the K1-A button to confirm the exit;
F1W1 range: The display range value of the W1 knob on the display screen, adjustable from 0 Pa 9999;
F2W2 range: The display range value of the W2 knob on the display screen, adjustable from 0 Pa 9999;
F3W3 range: The display range value of the W3 knob on the display screen, adjustable from 0 Pa 9999;
F4W4 range: The display range value of the W4 knob on the display screen, adjustable from 0 Pa 9999
F5A1 range: Display ADC1 feedback display range value, 0-5000 adjustable;
F6A2 range: Display ADC2 feedback display range value, 0-5000 adjustable;
Alarm current: Set the alarm value for ADC1 and ADC2 feedback display. When ADC1 and ADC2 exceed this value, the remote control display will alarm; when this value is 0,the alarm function is invalid;
8.Características eléctricas ar mando mbi

9.Tamaño ar mando mbi

Ar seki da interpretación ar final nuna ar producto pertenece únicamente ja ma empresa.