विवरण
1.उत्पादन मोडेल
मोडेल: DH01R-4W-26K
लागू उपकरण:विभिन्न औद्योगिक उपकरण
2.उत्पादन सामान रेखाचित्र
नोट: तपाईं तीन एन्टेना मध्ये एक छनोट गर्न सक्नुहुन्छ. सक्शन कप एन्टेना पूर्वनिर्धारित रूपमा मानक हो.
3.उत्पादन मोडेल विवरण
नोट:
① DH01R श्रृंखला, यदि प्रत्ययले T समावेश गर्दछ, it means with emergency stop output;without T, it means without emergency stop output.
②If there is no analog output, there is no need to remark 0W or 0R; the analogquantities W1, W2, W3, and W4 default to 0-10V analog voltage output; at the same time, W1 and W2 can be expanded to 2 isolated digital potentiometer outputs, with a range of 0 -5K ohms, ½ watt; resolution: 20 ohms. The two digital potentials can be used to control the welding current and welding voltage of the welding machine. If the digital potentiometer output is required, user notes are required.
④Analog input, ranging from 1 to 2, indicating that there are 1 to 2 एनालग इनपुटहरू(maximum 2 च्यानलहरू); when there is an analog input, you need to note the voltage range of the analog input (our receiver defaults to 0 -5वि, the user can also note as 4-20 mA or 0-10V, आदि) and the corresponding display range of the analog quantity (for example: display 0-100 volts or 0-1000 amps)
These two analog quantities can be used as displays for welding current and welding voltage.
4.विशेषताहरु
1)Maximum 26 वेल्डिङ मेसिन स्वचालन वेल्डिङ र वेल्डिङ अपरेटर। टर्न रोलहरू 1. फ्रिक्वेन्सी हपिङ ट्रान्समिशन टेक्नोलोजी प्रयोग गर्दै;
2)Maximum 4 एनालग 0-10V आउटपुटको च्यानलहरू (प्रदर्शन दायरा अनुकूलित गर्न सकिन्छ): समर्थन गर्दछ 2 विस्तारित पृथक डिजिटल potentiometer उत्पादन को च्यानल;
3)2 analog inputs; र रिमोट कन्ट्रोल मा प्रदर्शित, प्रदर्शन दायरा अनुकूलित गर्न सकिन्छ
4)1 channels of emergency stop relay output normally closed contacts;
5) Powered by 3 AA ब्याट्रीहरू, low power consumption design;
6) Wireless operation distance is 200 मिटर;
7)Protection grade IP67;
8)With cross switch operation, supports two 4-direction cross switches;
9)Back strap design.
5.Remote control switch description
6.Display content introduction
W1 knob value: W1: 0-1000 (parameter adjustable 0-9999)
W2 knob value: W2: 0-5000 (parameter adjustable 0-9999)
W3 knob value: W3: 0-5000 (parameter adjustable 0-9999)
W4 knob value: W4: 0-5000 (parameter adjustable 0-9999)
ADC1 feedback display: 0-1000 (parameter adjustable 0-5000)
ADC2 feedback display: 0-1000 (parameter adjustable 0-5000)
Low voltage: The remote control battery is too low, please replace the battery.
Network dropped: The wireless signal is interrupted. Please check the power of the receiver, power it on again, and restart the remote control.
7.Remote control function operation instructions
1) Turn on the remote control
When the receiver is powered on, the receiver working indicator flashes; install two AA batteries in the remote control, turn on the power switch, र प्रदर्शनले मान देखाउँछ,सफल स्टार्टअप संकेत गर्दछ. रिसीभर काम गर्ने सूचक प्रकाश ठोस हुन्छ.
2) स्विच र बटन प्रकार्यहरू
रिमोट कन्ट्रोलमा ट्विस्ट स्विच र बटनको कुनै पनि सञ्चालनले रिसीभरमा सम्बन्धित स्विच सिग्नल आउटपुट पोइन्टलाई नियन्त्रण गर्न सक्छ।. रिसीभरमा सबै स्विच सिग्नल आउटपुट बिन्दुहरू सामान्यतया पूर्वनिर्धारित रूपमा खुला संकेतहरू हुन्;
3)W1-W4 गति समायोजन
Rotate the knobs in W1-W4 arbitrarily to operate the corresponding analog output signal or potentiometer signal at the receiver end. The analog output signal at the receiver end defaults to a 0-10V voltage signal, and the potentiometer signal defaults to 0-5K;
4) Emergency stop function
When the emergency stop button is pressed, all switch signal outputs are disconnected and the analog output is disconnected; after the emergency stop is released, all switch signals are restored and the analog output is restored; 5 seconds after the remote control is turned off, all switch signal outputs are disconnected and the analog quantities remain unchanged. When the remote control is turned on, the switch signal outputs automatically recover;
5)Parameter menu (users are prohibited from modifying it privately)
Some functions of the remote control can be adjusted through parameters. When the display W1=0, press the K9-B button 3 times in a row, and then press the K9-A button 3 times in a row to enter the parameter menu; K9-A र K9-B मेनु मार्फत पृष्ठमा कुञ्जी र प्यारामिटरहरू चयन गर्नुहोस्; K1-A होल्ड गर्नुहोस्, र त्यसपछि प्यारामिटरहरू परिमार्जन गर्न K9-A/B बटन थिच्नुहोस्;
प्यारामिटर मेनुबाट बाहिर निस्कनुहोस्: बचत गर्न वा बचत नगर्ने छनौट गर्नुहोस्, र त्यसपछि निकास पुष्टि गर्न K1-A बटन थिच्नुहोस्;
F1W1 दायरा: डिस्प्ले स्क्रिनमा W1 knob को प्रदर्शन दायरा मान, बाट समायोज्य 0 to 9999;
F2W2 दायरा: डिस्प्ले स्क्रिनमा W2 knob को प्रदर्शन दायरा मान, बाट समायोज्य 0 to 9999;
F3W3 दायरा: प्रदर्शन स्क्रिनमा W3 knob को प्रदर्शन दायरा मान, बाट समायोज्य 0 to 9999;
F4W4 दायरा: The display range value of the W4 knob on the display screen, बाट समायोज्य 0 to 9999
F5A1 range: Display ADC1 feedback display range value, 0-5000 adjustable;
F6A2 range: Display ADC2 feedback display range value, 0-5000 adjustable;
Alarm current: Set the alarm value for ADC1 and ADC2 feedback display. When ADC1 and ADC2 exceed this value, the remote control display will alarm; when this value is 0,the alarm function is invalid;
8.Remote control electrical characteristics
9.Remote control size