Crawler hlau pom tshuab tsis siv neeg wireless chaw taws teeb tswj DH12S-LD

Tsev|industrial chaw taws teeb tswj|Crawler hlau pom tshuab tsis siv neeg wireless chaw taws teeb tswj DH12S-LD

Crawler hlau pom tshuab tsis siv neeg wireless chaw taws teeb tswj DH12S-LD

Daim ntawv thov:Tshwj xeeb yog siv rau crawler hlau saw tshuab

1.Txhawb tsis siv neeg txiav hom, cia li kho qhov kev taug kev ceev ntawm lub tshuab me me raws li lub cev muaj zog loj tam sim no, thiab ua tiav kev tswj tsis siv neeg txiav.

2.Barrier-free kis nrug deb yog 200 meters.

3. Txhawb kev tswj kev ceev dual rau cov motors loj thiab cov motors me.

4. Txhawb me me lub cev muaj zog tig rau hauv qhov chaw.

5. Txhawb sab laug thiab txoj cai log me me lub cev muaj zog linear kho.


  • Tsawg zog siv hluav taws xob tsim
  • Siv tau yooj yim

MKX-IV

Product model

Qauv: DH12S-LD

Applicable equipment:crawler wire saw machine

Daim Duab

Nco tseg: You can choose one of the three antennas. The suction cup antenna is standard by default.

Remote control switch description

Displaycontent introduction

Large motor speedS1:0-50
Small motor speed: S2: 0-50
Maximumspeedlimitofautomatic cuttingsmallmotor:F:0-30(parametersadjustable)
Automatic cutting maximum current: Ic: 0-35 (parameters adjustable)
Linear correction value: Df: -99-99 (1 unit is about 0.02V)

Low voltage: The remote control battery is too low, Thov hloov lub roj teeb.

Network dropped: The wireless signal is interrupted. Please check the power of the receiver, power it on again, and restart the remote control.

Remote control function operation instructions

1.Turn on the remote control

When the is powered on, the RF-LED light on the receiver starts to flash;Nruab ob lub roj teeb AA hauv throeceiver e cov chaw taws teeb tsuj, Qhib lub hwj chim hloov, Andthe cov zaub yuav qhia qhov kev nrawm nrawm, qhia tau tias muaj kev vam meej pib.

2.Loj Tsav Thiab Kev Tswj Ceev

Tig lub “Forward / Rov Qab” hloov mus rau tom ntej, Tus txais lub cev muaj zog loj yuav qhib, thiab cov zaub yuav qhia rau pem hauv ntej

Tig lub “Forward / Rov Qab” hloov mus rov qab, Lub cev muaj zog loj ntawm tus txais yuav tig rov qab, thiab cov zaub yuav qhia rov qab

Tig lub “Loj Tsav Nkaus Ceev” Lub pob qhov rooj los kho tus txais loj ceev ceev ceev hloov cov khoom siv voltage 0-10V;

3.ME MOJ THIAB CEEV COV KHIB

Txav mus “Forward / Rov Qab” hloov mus rau tom ntej, Lub log sab laug rau pem hauv ntej thiab txoj cai log rau pem hauv ntej ntawm tus txais yog muab, thiab cov zaub qhia rau pem hauv ntej

Tig lub “Forward / Rov Qab” hloov mus rov qab, sab laug lub log rov qab thiab txoj cai lub log rov qab ntawm tus txais yuav muab rau, thiab cov zaub qhia rov qab

4.Lem sab laug thiab sab xis

Tig lub “Sab laug / sab xis” Hloov mus rau sab laug, tus txais lub log sab xis yuav xa mus thiab tig mus,thiab cov zaub yuav qhia sab laug

Tig lub “lem sab laug / sab xis” hloov mus rau lem sab xis, lub log sab laug ntawm tus txais yuav xa mus rau pem hauv ntej thiab tig rau, thiab cov zaub yuav qhia sab xis lem

5.Tig rau hauv qhov chaw

Hauv phau ntawv hom:
Lem sab laug hauv qhov chaw: Nias thiab tuav tus “Ua kom txawj” lub khawm, tig lub “Sab laug / sab xis” Hloov mus rau sab laug, lub log sab laug rov qab thiab txoj cai log rau pem hauv ntej ntawm tus txais yuav muab rau,thiab pib tig mus rau hauv qhov chaw;

Lem sab xis hauv qhov chaw: Nias thiab tuav tus “Ua kom txawj” lub khawm, tig lub “Sab laug / sab xis” hloov mus rau sab xis, lub log sab laug rau pem hauv ntej thiab txoj cai log rov qab ntawm tus txais yog muab, thiab tus tau txais pib tig mus sab xis;

6.ME MOJ ME TSAV CEEV CEEV

Hauv hom hom: nias thiab tuav tus “Ua kom txawj” khawm thiab tig lub “Kev hloov kho me me ceev” to adjust the maximum speed of the small motor during automatic cutting;

7.Automatic cutting

The first step is to start the big motor; the second step is to switch the mode switch toAuto”; the third step is to start the small motor and the screen will displayCutting Auto”,indicating that it has entered the automatic cutting mode;

8. Straight line correction

When the left and right walking motors are moving forward and backward, the left and right speeds are inconsistent, and the straight-line walking deviates. You can use the linear correction function of the remote control to fine-tune the speed of the left and right wheels;
Correction principle: Through the correction function, the speed of the left wheel is fine-tuned to reach the same speed as the right wheel, yog li ua synchronize qhov ceev ntawm sab laug thiab sab xis log thiab tshem tawm cov kev sib txawv;
Kev sib txawv ntawm txoj kev ua haujlwm: Hauv phau ntawv hom, nias thiab tuav tus “Ua kom txawj” khawm thiab tig lub “Kev cai me me me”;
Tig moos ua kom nce lub log sab laug nrawm nrawm thiab tus nqi kho tus nqi ntawm cov zaub screen yuav nce ntxiv;
Tig counterclockwise kom txo qis lub log sab laug nrawm voltage thiab cov zaub kho kom tsawg dua;
Kho kho ntau yam: Kev kho tus nqi -90 rau 90; Kev kho kev kho hluav taws xob ntawm ib txoj kev kho kho yog hais txog 0.02V;

9. Parameter Menu (cov neeg siv raug txwv tsis pub hloov kho nws yam tsis tau kev tso cai)

Qee lub zog ntawm cov chaw taws teeb tswj tau tuaj yeem hloov kho los ntawm kev txwv. Hauv phau ntawv hom, Thaum lub cev muaj zog me me S2 yog 10, thawb rau pem hauv ntej / rov qab hloov peb zaug uake, thiab tom qab ntawd thawb nws cia peb zaug nyob rau hauv kab los ntaus cov ntawv qhia zaub mov parameter;
Tawm ntawm Parameter Menu: choose to save or not save, then press the enable button to confirm the exit;
Maximum current: the operating rated current of the cutting motor is 80% of this currentt;
Speed control parameters: automatic cutting control parameters, default 800, modification is prohibited;
Deceleration parameter: automatic cutting control parameter. When the cutting current change value exceeds this value,deceleration begins.
Acceleration a1: automatic cutting control parameter, when the cutting current is lower than the set cutting current, the speed of acceleration;
Deceleration a2: automatic cutting control parameter, when the cutting current is higher than the set
cutting current, the speed of deceleration;
Automatic knife retraction: invalid;
Start self-locking: 0, no self-locking; 1, self-locking. Press the enable key + forward and reverse to take effect and self-lock.
Maximum walking: the maximum speed of the small motor.
Cutting current: set the maximum current of the main motor for automatic cutting. If the feedback current exceeds this value, it will start to decelerate.
Default speed limit: the default maximum speed of automatic cutting speed when turning on the machine.
Automatic mode: 0, the automatic switch is automatically controlled; 1, the automatic switch controls the automatic IO output point.
Speed limit offset: the maximum speed of the small motor during automatic cutting.
Maximum host: maximum speed of large motor.

Remote control electrical characteristics

Remote control size

The final interpretation right of this product belongs only to our company.

MKX-IV

Wixhc Technology

Peb yog tus thawj coj hauv CNC kev lag luam, tshwj xeeb hauv wireless kis thiab CNC tswj kev tswj hwm rau ntau tshaj 20 xyoo. Peb muaj ntau ntau lub thim thim thev naus laus zis, thiab peb cov khoom muag muag zoo hauv ntau dua 40 cov teb chaws thoob qab ntuj, zeem tau cov kev siv ntawm yuav luag 10000 cov qhua tuaj noj mov.

Tsis ntev los no Tweets

Cov ntawv xov xwm

Sau npe nkag kom tau txais cov xov xwm tshiab thiab hloov cov ntaub ntawv. Txhob txhawj, peb yuav tsis xa spam!