Beskriuwing
1.Product model
Model: DH01R-4W-26K
Applicable equipment:various industrial equipment
2.Product accessories diagram
Noat: You can choose one of the three antennas. The suction cup antenna is standard by default.
3.Product model description
Noat:
① DH01R series, if the suffix contains T, it means with emergency stop output;without T, it means without emergency stop output.
②If there is no analog output, there is no need to remark 0W or 0R; the analogquantities W1, W2, W3, and W4 default to 0-10V analog voltage output; at the same time, W1 and W2 can be expanded to 2 isolated digital potentiometer outputs, with a range of 0 -5K ohms, ½ watt; resolution: 20 ohms. The two digital potentials can be used to control the welding current and welding voltage of the welding machine. If the digital potentiometer output is required, user notes are required.
④Analog input, ranging from 1 to 2, oanjout dat der binne 1 to 2 analoge yngongen(maksimum 2 kanalen); as der in analoge ynfier, jo moatte it spanningsberik fan 'e analoge ynfier notearje (ús ûntfanger standert oan 0 -5V, de brûker kin ek notearje as 4-20 mA of 0-10V, ensfh.) en it oerienkommende werjefteberik fan 'e analoge kwantiteit (bygelyks: skerm 0-100 volt of 0-1000 amps)
Dizze twa analoge hoemannichten kinne brûkt wurde as displays foar lasstrom en lasspanning.
4.Funksjes
1)Maximum 26 relay útgongen;
2)Maximum 4 kanalen fan analoge 0-10V útfier (display berik kin wurde oanpast): stipet 2 kanalen fan útwreide isolearre digitale potensiometer útfier;
3)2 analog inputs; en werjûn op de ôfstânsbetsjinning, it display berik kin wurde oanpast
4)1 channels of emergency stop relay output normally closed contacts;
5) Powered by 3 AA batterijen, low power consumption design;
6) Wireless operation distance is 200 meters;
7)Protection grade IP67;
8)With cross switch operation, supports two 4-direction cross switches;
9)Back strap design.
5.Remote control switch description
6.Display content introduction
W1 knob value: W1: 0-1000 (parameter adjustable 0-9999)
W2 knob value: W2: 0-5000 (parameter adjustable 0-9999)
W3 knob value: W3: 0-5000 (parameter adjustable 0-9999)
W4 knob value: W4: 0-5000 (parameter adjustable 0-9999)
ADC1 feedback display: 0-1000 (parameter adjustable 0-5000)
ADC2 feedback display: 0-1000 (parameter adjustable 0-5000)
Low voltage: The remote control battery is too low, please replace the battery.
Network dropped: The wireless signal is interrupted. Please check the power of the receiver, power it on again, and restart the remote control.
7.Remote control function operation instructions
1) Turn on the remote control
When the receiver is powered on, the receiver working indicator flashes; install two AA batteries in the remote control, turn on the power switch, and the display shows a value,indicating successful startup. The receiver working indicator light becomes solid.
2)Switch and button functions
Any operation of the twist switch and button on the remote control can control the corresponding switch signal output point on the receiver. All switch signal output points on the receiver are normally open signals by default;
3)W1-W4 speed adjustment
Draai de knoppen yn W1-W4 willekeurich om it korrespondearjende analoge útfiersinjaal as potentiometersinjaal oan 'e ûntfanger te betsjinjen. It analoge útfiersinjaal oan 'e ûntfanger ein is standert op in 0-10V spanningsinjaal, en it potensiometersinjaal is standert op 0-5K;
4) Emergency stop funksje
As de needstopknop yndrukt wurdt, alle switch sinjaal útgongen wurde loskeppele en de analoge útfier wurdt loskeppele; neidat de needstop wurdt loslitten, alle switch sinjalen wurde restaurearre en de analoge útfier wurdt restaurearre; 5 seconds after the remote control is turned off, all switch signal outputs are disconnected and the analog quantities remain unchanged. When the remote control is turned on, the switch signal outputs automatically recover;
5)Parameter menu (users are prohibited from modifying it privately)
Some functions of the remote control can be adjusted through parameters. When the display W1=0, press the K9-B button 3 times in a row, and then press the K9-A button 3 times in a row to enter the parameter menu; K9-A en K9-B-kaai om troch it menu te blêdzjen en parameters te selektearjen; hâld K1-A yn, en druk dan op de K9-A/B knop om parameters te feroarjen;
Gean út it parametermenu: kieze om te bewarjen of net te bewarjen, en druk dan op de K1-A knop om de útgong te befêstigjen;
It hannelvolumint fan 'F1W1: De werjefteberikwearde fan 'e W1-knop op it displayskerm, ferstelbere út 0 to 9999;
It hannelvolumint fan 'F2W2: De wearde fan it werjaanberik fan 'e W2-knop op it displayskerm, ferstelbere út 0 to 9999;
It hannelvolumint fan 'F3W3: De wearde fan it werjaanberik fan 'e W3-knop op it displayskerm, ferstelbere út 0 to 9999;
De priis fan F4W4: The display range value of the W4 knob on the display screen, ferstelbere út 0 to 9999
F5A1 range: Display ADC1 feedback display range value, 0-5000 adjustable;
F6A2 range: Display ADC2 feedback display range value, 0-5000 adjustable;
Alarm current: Set the alarm value for ADC1 and ADC2 feedback display. When ADC1 and ADC2 exceed this value, the remote control display will alarm; when this value is 0,the alarm function is invalid;
8.Remote control electrical characteristics
9.Remote control size
The final interpretation right of this product belongs only to our company.