Wire saw misini ni kotiva vakaikoya na yawa yawa DH12S-P6S

Vale|iVakasaribaria vakayawa ni isoqosoqo|Wire saw misini ni kotiva vakaikoya na yawa yawa DH12S-P6S

Wire saw misini ni kotiva vakaikoya na yawa yawa DH12S-P6S

iVolakerekere:Vakayagataki vakatabakidua me baleta na misini ni ivakatakilakila ni wa

1.Tokona na cakacaka ni kotiva vakaikoya, automatically adjusts cutting speed according to motor current feedback

2.Na yawa ni vanua e vakau galala tu kina na itatarovi e 200 mita.

3. Veitokoni ni draiva ni DC.

4. Tokona na ivakarau ni kotiva na ivakarau ni kotiva, me vaka na kotiva na kui, iyalayala ni totolo, kei.

5. Tokona na veisau ni itaukei ni wa kei na ivakarau ni sarasere. Na duidui ni ivakarau ni kotiva e rawa ni tuvanaki ena veimataqali ivakarau.


  • Veivakarusai ni kaukauwa e lailai
  • Rawarawa ni vakayagataki

iVakamacala

1.Product model

 

iVakaraitaki: DH12S-P6S

Applicable equipment:wire saw/blade saw machine

2.Product accessories diagram

Me Kilai: You can choose one of the three antennas. The suction cup antenna is standard by default.

3.Remote control switch description

4.Displaycontent introduction

Main motor speed: Main: 0-50
Traveling motor speed: Line: 0-50
Maximum speed limit of automatic cutting traveling motor: Speed: 0-30
(parameters adjustable)
Automatic cutting main motor setting current: Setting: 28 (parameters adjustable)
Swing arm motor speed: Swing: 0-50

Low voltage: The remote control battery is too low, please replace the battery.

Network dropped: The wireless signal is interrupted. Please check the power of the receiver, power it on again, and restart the remote control.

5.Remote control function operation instructions

1)Turn on the remote control

When the receiver is powered on, the D2 power light on the receiver is always on, andthe D1 signal light starts to flash; install two AA batteries in the remote control, turn on the power switch, and the display will show the motor speed, indicating successful startup.

2)Large motor and speed regulation/Main motor and speed regulation

Press and holdSpeed Regulation Enable”, turn theForward/Reverseswitch to forward, and the receiver’s main motor will turn on;
Press and holdSpeed Regulation Enable”, turn theForward/Reverseswitch to reverse, and the receiver’s main motor will reverse and turn on;Simply move the switch to the middle or reverse direction, and the main motor will stop immediately without pressing the speed control enable button;Rotate thebig motorknob to adjust the speed regulation voltage of the receiver’s main motor inverter to 0-10V;

3)Traveling motor

Press and holdSpeed Adjustment Enable”, turn theForward/Reverseswitch to forward or backward, and the walking motor will move at a high speed of 50;

4)Swing arm motor and speed regulation

Turn theSwing Arm/Reverseswitch to swing arm or retreat, and the receiver’s swing arm motor starts; then rotate theSpeed Adjustmentknob to adjust the swing arm motor speed;

Press and holdSpeed Adjustment Enable”, and then pull theSwing Arm/Reverseswitch, the swing arm motor will move at a high speed of 50;

5)Travel motor speed limit adjustment

Press and hold thespeed adjustment enablebutton and rotate thespeed adjustmentto adjust the maximum speed limit of the traveling motor during automatic cutting;

6) Automatic cutting

The first step is to start the main motor; the second step is to adjust the maximum speed limit of the walking motor; the third step is to move theforward/reverseswitch forward or backward to enter the automatic cutting mode;

7) Parameter menu (users are prohibited from modifying it without permission)

Enter the parameter menu:In manual mode, when the main motor speed is 0, push the forward/reverse switch up three times in a row, and then push it down three times in a row to enterthe parameter menu;
Exit the parameter menu: Turn the speed adjustment knob, select save or not save, and press the enable button to confirm;
Rated current: The maximum value of the main motor current, unit Ampere;
Speed adjustment parameters: Automatic cutting control parameters, default 800, unit milli second,modification is prohibited;
Deceleration parameter: When the cutting current change value exceeds this value, rapid deceleration begins, unit Ampere;
Acceleration a1: When the cutting current is lower than the set cutting current, the speed value increased by each acceleration of the walking motor;
Deceleration a2: When the cutting current is higher than the set cutting current, the speed value reduced by each deceleration of the walking motor;
Swing arm current: Default value, modification is prohibited;
Stop time: After the automatic mode current overload shutdown, the current will be detected again after a period of time. If it is less than the set current, the walking motor will automatically start; unit second, default value, modification is prohibited;
Maximum current: The range of main motor feedback current, unit Ampere;
Maximum host: Remote control main motor speed adjustment display range;
Maximum walking: Invalid parameter;
Speed limit offset: During automatic cutting, the remote control display walking motor speed limit = 50% of this parameter;
Increase sensitivity: When the main motor feedback current increases, each time the increase exceeds this value, the walking motor accelerates;
Decrease sensitivity: When the feedback current of the main motor decreases, and each time the decreasing value exceeds this value, the walking motor decelerates;
Sensitivity offset: Add and subtract the offset increment of the sensitivity parameter;
Set current: Automatic cutting, the threshold of main motor feedback current. If this value is exceeded,the walking motor starts to decelerate;Below this value, the walking motor starts to accelerate;unit: Ampere;
Idling exit: When the automatic mode starts, if the main motor feedback current is less than this value,it will be in the idling mode.If it is greaterthan this value, it will exit the idling mode and enter the cutting mode.Unit is ampere;
No-load current:When automatic mode starts, if the main motor feedback current is less than this value,it is in no-load mode.If it is greaterthan this value, it will exit the no-load mode and enter the cutting mode.Unit is Ampere;
Swing arm speed: Initial speed of swing arm motor when starting up;
Cutting mode: Switch between blade saw and wire saw modes, and the parameters will switch accordingly after the switch; in blade saw mode, the remote control display adds a swing arm motor, while in wire saw mode, there is no swing arm motor;
Debounce time: When the main motor feedback current exceeds the stop current, the feedback current will be continuously detected. The debounce time is the duration of this continuous detection.After this time, if the main motor current still exceeds the stop current, the walking motor will stop;otherwise, the walking motor will stop. The motor will keep going;
Stop current: The main motor feedback current exceeds this value, and the walking motor will stop;Unit is Ampere;
Offset default: The initial value of the walking motor speed limit when the remote control is turned on = 50% of this value;

6.Remote control electrical characteristics

7.Remote control size

The final interpretation right of this product belongs only to our company.

Yatuvaki matailalai

Wixhc tekinolaji

Eda sa dua na iliuliu ena kabani ni CNC, vakamataitaki ena vakau ni veicuruqaqa kei na CNC Motion Control me sivia na 20 yabaki. Sa tu vei keda e vica vata na daseni na tekinolaji ni dodonu, ka volitaka vakavinaka cake na noda ivoli mai na 40 veimatanitu e veiyasai vuravura, vakasoqona na kena ivolakerekere volekata ni 10000 kasitama.

Tweet Wale Tikoga Oqo

iVola ni itukutuku